Where does the signal come from? Source and the 10-20 system
The EEG measured on the scalp is not the sum of individual action potentials but largely of the postsynaptic potentials of cortical pyramidal neurons. Because these cells are arranged perpendicular to the surface, their fields add up when activated together, and they behave like a small dipole.
The skull strongly attenuates and spreads the signal. For a spike to be visible on the scalp, several square centimetres of cortex generally need to be active synchronously. This is why a normal EEG does not exclude epilepsy; deep or small foci may not be seen.
Naming the electrodes
The international 10-20 system provides placement proportional to head size: it uses 10% and 20% intervals of the distances between nasion and inion and between the two preauricular points. Thus the same region has the same name on heads of different size.
- Letters show the region: Fp frontopolar, F frontal, C central, P parietal, O occipital, T temporal.
- Odd numbers are left, even numbers right; z marks the midline.
- The 10% system is used for denser placement; here the temporal electrodes are named T7, T8, P7, P8 (formerly T3, T4, T5, T6).
- An inferior temporal row (F9, F10, T9, T10, P9, P10) helps detect temporal lobe foci.