Neuromuscular junction: repetitive stimulation
A healthy junction has a safety margin: every fibre fires even if acetylcholine release falls. When this margin is lost, some muscle fibres fail to fire and the CMAP shrinks with repeated stimulation. This principle separates postsynaptic from presynaptic disorders.
Basic distinction
| Condition | Low frequency (2-5 Hz) | Resting CMAP | Brief exercise or high frequency |
|---|---|---|---|
| Myasthenia gravis | > 10% decrement | Usually normal | Short-lived improvement, then exhaustion |
| Lambert-Eaton | Decrement | Usually low | Marked increment (≥ 60%, often ≥ 100%) |
| Botulism | Variable | Low | Mild to moderate increment possible |
For low-frequency testing the limb is immobilised and the patient should be rested and warm. A cholinesterase inhibitor is stopped a few hours beforehand if possible. Proximal muscles (trapezius, deltoid) and facial muscles are more sensitive than distal ones.
Single-fibre EMG
Increased jitter on single-fibre EMG is the most sensitive test for impaired neuromuscular transmission, but it is not specific. Nerve or muscle disease can also increase jitter.